SICK LD-LRS
上一个:
下一个:
At a glance
- Long scanning range, even when detecting dark surfaces
- High angular resolution of up to 0.0625 degrees
- High immunity to solar radiation
- Synchronous monitoring of up to four different fields
- Small laser spot diameter even at long distances
Your benefits
-
Reliable operation even in harsh ambient conditions
-
Low installation costs due to large monitoring area
-
Reliable detection of small objects at long distances
-
Easy installation options for excavators and crane systems
Technical Data
Features |
|
Field of application |
Outdoor |
Version |
Long Range |
Light source |
Infrared (905 nm) |
Laser class |
1 (EN/IEC 60825-1), eye-safe |
Field of view |
360 ° |
Scanning frequency |
5 Hz ... 10 Hz |
Angular resolution |
0.062 °,0.125 °,0.25 °,0.5 °,1 °,1.5 ° |
Heating |
Yes |
Operating range |
2.5 m ... 250 m |
Max. range with 10 % reflectivity |
80 m |
Performance |
|
Response time |
≥ 100 ms |
Detectable object shape |
Almost any |
Systematic error |
± 38 mm |
Statistical error |
± 30 mm |
Integrated application |
Field evaluation |
Number of field sets |
4 fields |
Simultaneous processing cases |
4 |
Interfaces |
|
Serial (RS-422) |
|
Data transmission rate (Serial (RS-422)) |
4,800 Baud ... 115,200 Baud |
Ethernet |
|
Data transmission rate (Ethernet) |
≤ 10 Mbit/s |
Protocol (Ethernet) |
TCP/IP |
CAN bus |
|
Protocol (CAN bus) |
Standard 2.0.A |
Data transmission rate (CAN bus) |
10 kbit/s ... 1 Mbit/s |
PROFIBUS DP |
- |
PROFINET |
- |
DeviceNet |
- |
Switching outputs |
4 (digital) |
Optical indicators |
0 |
Mechanics/electronics |
|
Electrical connection |
1 x 20-pin Harting plug |
Operating voltage |
24 V DC± 15 % |
Power consumption |
36 W, + 140 W heating |
Housing |
PU (polyurethane rigid integral foam) |
Housing color |
Gray (RAL 7032) |
Enclosure rating |
IP 67 |
Protection class |
III |
Weight |
9.1 kg |
Dimensions |
250 mm x 350 mm x 391.1 mm |
Ambient data |
|
Ambient operating temperature |
-25 °C ... +50 °C |
Storage temperature |
-25 °C ... +70 °C |